R22 subcooling chart

Actual Line Temp – Sat Temp = Total Superheat. 55°F - 37°F = 18°F. 18°F of Total Superheat > 9°F Target Superheat = Undercharged. Since the actual total superheat measured is higher than the target superheat, we would need to add refrigerant a little at a time until the superheat is the same as the target superheat.

R22 subcooling chart. Why is knowing how to read the subcooling chart r22 important? Experts Typically Recommend A Range Of 10 To 15 Degrees Fahrenheit. Here is how we use the. So, what’s the ideal subcooling range for r22? Optimal subcooling range for r22. The Primary Tool For The Job Is A Superheat/Subcool Meter Or Gauge.

SuperCool Slide Rule. $19.99. Quantity. Add to Cart. PRODUCT INFO. SuperCool Slide Rule - R22 & R410a Charging & Duct Calculator - Air Conditioning and HVAC Troubleshooting, A/C Educational Products, & AC Charts - SuperHeat & SubCooling.

EXAMPLE 2. CHECKING SUBCOOLING. Subcooling on systems that use thermostatic expansion valve (TXV) is approximately 10°F to 18°F. To check subcooling on a R-22 system, I will need to attach a thermometer near the liquid line at the condenser. Suppose my temperature reading is 90°F. I would then take the head pressure.Or download onto your own device. P-T Calculator. This comprehensive Pressure/Temperature calculation tool provides several unique features designed to make the HVAC/R technician’s job easier. Available for iOS and Android devices: For more information, call 800-262-0012. or e-mail [email protected] our newfound knowledge of how to read the P-H diagram, we can easily see that the compressor increases the pressure of the refrigerant, since the line is moving up. The compressor also superheats the refrigerant a bit, since the line moves out to the right of the saturation dome. Point 2: Here’s our condenser line.16 Oct 2013 ... Manufacturers of refrigerants, controls, and other suppliers distribute hundreds of thousands of pressure-temperature charts to the trade ...A plywood weight chart displays the weights for different thicknesses of plywood. Such charts also give weights for plywood made from different materials and grades of material. To...

19 Jan 2021 ... How To Add Refrigerant To Your Air Conditioner R410A & R22. The DIY ... How To Refill R22 AC With Subcooling Method. Word of Advice TV•330K ...Target subcooling is higher than measured subcooling (low subcooling situation). Example: In an R-22 system, we see that target subcooling should be 11°F, but ... R22 Alternatives. R32. R404A. R404A Alternatives. R407C. R410A. R454B. ... Subcooling Calculator. This tool is only available on devices with appropriate screen size. According to the R-22 PT chart, this is equal to about 54°F. With the thermometer, we measured the saturated R-22 temperature of 45°F. Here is how we can calculate the R-22 superheat in this system: Superheat (R-22) = 54°F – 45°F = 9°F. The superheat calculator also gives us 9°F superheat for R-22 refrigerant.This document will explain how to read a pressure temperature chart for super-heat and sub-cooling calculations. Product line: All DX Cooling units. …

R-407C is a zeotropic blend of R-32 (Difluromethane), R-125, and R-134a (Tetrafluoroethane). It is not a drop in replacement on R-22 machines. If you wish to use this product you will need to vacate all of the old R-22 out of the system. This is due to the R-22 systems using mineral oil and this HFC blend using POE oil.Even if a system charge is available, you want to check superheat. And you want to check subcooling, more so as a reality check. 30ºF subcooling suggests to me that your orifice is too small. If we have data, let’s look at data. If all we have are opinions, let’s go with mine. – Jim Barksdale, former Netscape CEO.DATE: 14.02.2012 Author: wallkitli r22 superheat table Thermodynamic Properties of DuPont(tm) Freon(R) 22 (R-22. R22 Superheat Subcooling Calculator Charging Chart [Refrigerant Reference] on Amazon.com. *FREE* super saver shipping on qualifying offers. This is a very useful tool. R22 Superheated Table - Libros-En-PDF.com This linked …Measure compressor in temperature on the suction line near the compressor. 5. Calculate the amount of compressor superheat. Compressor superheat is all the superheat the compressor “sees.”. It is a combination of evaporator and suction line superheat. Compressor superheat is sometimes referred to as total superheat. 6.In this podcast episode, we ONCE AGAIN talk about superheat and subcooling. This episode is a recap to help people who struggle with the concept. You get superheat when you have 100% vapor, and you have subcooling when you have 100% liquid; any liquid-vapor mixtures are in a saturated state. We usually measure superheat outside at the …

Pole buildings living quarters.

145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart:145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart:Or download onto your own device. P-T Calculator. This comprehensive Pressure/Temperature calculation tool provides several unique features designed to make the HVAC/R technician’s job easier. Available for iOS and Android devices: For more information, call 800-262-0012. or e-mail [email protected] Alternatives. R32. R404A. R404A Alternatives. R407C. R410A. R454B. ... Subcooling Calculator. This tool is only available on devices with appropriate screen size.For detailed charging instructions see installation instructions provided with unit. Measure air temperature to outdoor coil for cooling and indoor coil for heating. Place and "X" on the appropriate chart w here the suction and discharge pressures cross. If "X" is below ambient temperature line, add charge and repeat step 3.Don't be fooled by an abridged chart with missing information, tidbits of random formulas and rule of thumb calculations all crammed on to one chart. The HVAC 3-Pack comes with 3 charts. One for sizing ductwork, one for calculating superheat/subcooling on R-22 systems and one for calculating superheat/subcooling on R-410a systems.

If it were R22, the green scale would show us 75°F for the very same pressure. Superheat and subcooling. The temperature deviates from the P-T relationship outside the evaporator and condenser. In these cases, superheating or subcooling has occurred. Superheated vapor is hotter than the saturation temperature.This 3D video shows setting a charge by subcool on a TXV system In 3D. Learn how to charge a TXV air conditioner or heat pump using the sub cooling method wi...Pressure Temperature Charts °F °C R-22 60 15.6 102 65 18.3 111 70 21.1 121 75 23.9 132 80 26.7 144 85 29.4 156 90 32.2 168 95 35.0 182 100 37.8 196 105 40.6 211 110 43.3 226 115 46.1 243 120 48.9 260 125 51.7 278 130 54.4 297 135 57.2 317 140 60.0 337 145 62.8 359 150 65.6 382 Vapor Pressure in PSIGJan 13, 2022 · Subcooling of refrigerant R22 = Temperature of saturated refrigerant R22 – Temperature of liquid line. The measurement of both temperatures can be done by a few steps discussed in the topic above. You can visit the above topic for more detail on practical how-to measure temperature and pressure for calculation. The chemical name of the R22 is ... Units manufactured after 7/09 used this subcooling chart. Check out the 036 unit at 12 SC. Then Lennox updated the chart with this update on 5/13. Somehow a 036 unit goes from 12 SC to 4 SC without any changes to the product. So I am charging a 13ACX-036 per the new label at 4 SC.Our subcooling chart will help you understand subcooling levels for different refrigerants, making it easier to maintain your system… Subcooling Chart: Your Ultimate Guide to …R22 superheat subcooling calculator charging chart on galleon philippinesCharging superheat chart calculator subcooling r22 amazon r410a Subcooling hvac load without pm vbb talkDesigned subcooling. Check Details Charge chart subcooling refrigerant questions using information adjustment checking typical figure.R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 – 02/22. Created Date: 2/25/2022 1:24:53 PM ...TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced …With a manifold gauge (and via R-22 PT chart), we measure the saturated refrigerant temperature of 89°F. The clamp-on thermometer reads 77°F. Here is how we use the subcooling formula to manually calculate the subcooling in this system: Subcooling (R-22) = 89°F – 77°F = 12°FHow To Calculate Subcooling? Formula, Subcooling Calculator (R22, 410A, etc.) · Subcooling Formula. We only need to subtract the subcooled liquid refrigerant ...To check superheat: 1. Attach a thermometer designed to take pipe temperature to the suction line. Don't use an infrared thermometer for this task. 2. Then take the suction pressure and convert it to temperature on a temperature/pressure chart. Subtract the two numbers to get superheat.

To determine the Target Superheat for an air conditioning system with a fixed orifice (such as a piston or capillary tube) measure the indoor WB (wet bulb) temperature with a digital psychrometer and the outdoor DB (dry bulb) temperature with a standard digital temperature reader. Input these temperatures in a superheat chart, …

TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ... But if you take a charging chart and plug in the numbers, it comes out the same. +/- a cou [ple of degrees. example: Carrier R22 chart wet bulb 66 condenser 90 required Sh 13 @70 psi suction. 3 x 66=198 198-80= 118 118 - 90=28 28/2 =14 sh Don't know why but it works. Doug.For detailed charging instructions see installation instructions provided with unit. Measure air temperature to outdoor coil for cooling and indoor coil for heating. Place and "X" on the appropriate chart w here the suction and discharge pressures cross. If "X" is below ambient temperature line, add charge and repeat step 3.24 May 2016 ... HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is ...piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R-22 and R-410A...Superheat Charging Chart- How to Find Target Superheat and Actual Superheat on an Air Conditioner! Calculate the Wet Bulb and Dry Bulb Temp using the chart t...For detailed charging instructions see installation instructions provided with unit. Measure air temperature to outdoor coil for cooling and indoor coil for heating. Place and "X" on the appropriate chart w here the suction and discharge pressures cross. If "X" is below ambient temperature line, add charge and repeat step 3.8 Feet Maximum. STEP 2 - Remove the pressure tap cap and valve cores from both service valves. STEP 3 - Purge the refrigerant lines and indoor coil with dry nitrogen. STEP 4 - Wrap a wet rag around the valve body to avoid heat …

Walmart supercenter paris texas.

Restaurants in north platte.

1. Take the low side pressure reading from your gauges and convert it to temperature using chart or gauge. 2. Then take the temperature of the Suction line as close to the condensing section as possible stay at least 6 inches from compressor. 3. Take the difference between the above readings (Suction line temp – Saturation temp) 4.R407c is an HFC refrigerant that will replace the R22 refrigerant, as per Montreal Protocol. It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will ...Subcooling is the same temperature difference on the high side. “In the example given earlier, suction pressure of 118 psi converts to a saturated temperature of 40°. If the suction gas is 50°, then there is 10° of superheat,” he said. “Too much superheat means the compressor is not being cooled properly and can overheat.9,546. Post Likes. Subcooling should be around 12-15, but you need to measure your superheat to see what's happening in the system. those pressures seem low for 90 degrees, but without more readings it a guess. SH/SC,ambient, delta t,ect.Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...1. a) Most walk-in coolers and freezers use a TX valve to regulate the flow of refrigerant into the evaporator. If the superheat is low the TX valve will allow refrigerant to flow into the evaporator at a rate that exceeds the capacity of the evaporator and as a result liquid will enter the suction line.In the case of a blend, you Simply read the saturated temperature next to the pressure in the vapor (dew point) column of the chart. When checking the subcool condition the technician will measure the temperature of the liquid line, and the pressure at that point and subtract the measured temperature from the saturated temperature at the end of ...145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart:Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Tons o f Refrigeration - 2 00 Feet Equivalent Pipe Length. Re frigerants 22, 134a, 404,A and 507values are based on 100° F liquid temperatureand the stated evaporator temperature. R e frigerant 717 (ammonia) values are b ased o n 86° F liquid temperature and 20° F evaporator temperature. Both s uction a n d liquid line values a re based on a ...it must have a full line of properly subcooled liquid refrigerant all the way to the inlet. On a split system, checking the subcooling at the condensing unit is ... ….

Actual Line Temp – Sat Temp = Total Superheat. 55°F - 37°F = 18°F. 18°F of Total Superheat > 9°F Target Superheat = Undercharged. Since the actual total superheat measured is higher than the target superheat, we would need to add refrigerant a little at a time until the superheat is the same as the target superheat.Gantt charts can be versatile tools for project management when used correctly. However, if you’re part of an organization that regularly uses them, you’re also probably aware that...R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi gIn today’s data-driven world, charts are an essential tool for visually representing information and making it easier to understand. Whether you’re a student, professional, or just...R22 to r134 conversion. here goes, all factoryR22 goodman superheat subcooling calculator R22 chart superheat charging temperature curves line system orifice split liquid subcooling r410a cooling tables compressor metering txv device york21 new r22 charging chart.Warning: Do not attempt to troubleshoot refrigerant charge on central air conditioning units unless you are EPA 608 type II Certified. This article refers to troubleshooting refrigerant charge on 410a and R22 residential air conditioning systems. Although many of the principles will carry over to other types of refrigerants and drop-ins. I will be sharing a …Subtract the Liquid line Temperature from the Liquid Saturation Temperature and you get a Subcooling of 15. “Typically” on TXV systems the Superheat will range between 8 to 28 degrees with a target of about 10 to 15 degrees. The Subcool range on TXV systems will range from about 8 to 20.November 12, 2020. Change is coming once again to the HVACR industry, as there is a growing movement to transition from R-410A to lower-GWP refrigerants. California, for example, is proposing a GWP limit of 750 for all new stationary air conditioning systems (residential and commercial) in California starting Jan. 1, 2023, and other states are ...R22 Subcooling Charging Chart. Superheat hvac subcooling orifice troubleshooting acting slidesharetri.. Redken Eq Gloss Color Chart. Eq redken gloss redken eq wella shade demi palette toning toner brassy.. Chewtle Evolution Pokemon Sword. evolve chewtle pumpkaboo galar shield sword gourgeist chewtle drednaw.. R22 subcooling chart, 145 °F. 571.7 psig. 150 °F. 607.6 psig. 155 °F. 645.2 psig. You can see that this R410A pressure chart includes high and low side pressures at temperatures ranging from -60 °F to 155 °F. Higher temperature equates to higher pressure. Here are 4 examples of how you can use this chart:, charged to 7 to 9 ºF subcooling at the indoor unit. 7. Maximum equivalent length of line set is: a. 250 feet (76.2 m) for single stage units with scroll or reciprocating compressors. b. 150 feet (45.7 m) for single stage units with rotary compressors. c. 150 feet (45.7 m) for two stage units. 8. Maximum linear length of line set is: a., Checking with reputable linen and bedding companies through their online portals is an easy way to find size charts for each company’s pillows. Each manufacturer sizes pillows acco..., The chart of military ranks is an important tool for understanding the structure of the armed forces. It provides a clear and concise overview of the various ranks and their associ..., Today I had a r22 goodman unit that was low on charge. 50 degrees superheat with no subcooling on a piston system. I charged the system up by superheat. I left it at 17 degrees superheat and 5 degrees subcooling. ... Carrier R22 chart wet bulb 66 condenser 90 required Sh 13 @70 psi suction 3 x 66=198 198-80= 118 118 - 90=28 28/2 …, In this HVAC Video, I go over what Subcooling to set an Air Conditioning System to if the rating plate is worn off. I also go over how to figure out what ref..., Each Goodman air conditioner comes with a data plate that provides information about the correct amount of refrigerant needed for the system. However, a generalized charging process might look something like this: Check the outdoor temperature. This will be used to find the target superheat or subcooling., Graphs and charts are used to make information easier to visualize. Humans are great at seeing patterns, but they struggle with raw numbers. Graphs and charts can show trends and c..., 4) Actual line temperature should = chart temperature above. 5) If more than 5 degrees over, add charge to decrease line temperature. 6) If more than 5 degrees under, remove charge to increase line temperature. R22 TXV CHARGING CALCULATOR Based on 15 degrees sub-cooling Gauge Line Gauge Line Press. Temp. Press. Temp. 134 61 233 …, Use a fixed orifice charging chart like the one pictured below to obtain proper superheat. For Example, if the wet bulb temp reading is 68°F and the outdoor dry bulb temp reading is 90°F then the required superheat will be 14°F, according to the charging chart below. Superheat with a TXV. HVAC systems containing a TXV should be charged by ..., R448a PT chart is quite useful in HVAC. It tells you what is the pressure of R488a liquid and vapor refrigerant from -49°F to 150°F.Inversely, you can also tell the temperature of R488a refrigerant if you know the pressures (from 0.7 psig to 462.8 psig)., Our subcooling chart will help you understand subcooling levels for different refrigerants, making it easier to maintain your system… Subcooling Chart: Your Ultimate Guide to …, Superheat r410a subcooling 134a heat. Piston sizing chart peugeot mopedarmy retrieved oldid title index410a refrigerant cost per pound : shop 25r410a r410a refrigerant Piston size chart r22 goodman06dr1090 carrier refrigeration 5h40 compressor spares part, view. R 22 piston sizing chartPiston size chart r410a goodman Recovery …, a refrigerating system, exclusive of any subcooling or superheating. This term usually describes condensation or evaporation of a zeotrope. ODP – ozone depletion potential – …, In this podcast episode, we ONCE AGAIN talk about superheat and subcooling. This episode is a recap to help people who struggle with the concept. You get superheat when you have 100% vapor, and you have subcooling when you have 100% liquid; any liquid-vapor mixtures are in a saturated state. We usually measure superheat outside at the …, 1. a) Most walk-in coolers and freezers use a TX valve to regulate the flow of refrigerant into the evaporator. If the superheat is low the TX valve will allow refrigerant to flow into the evaporator at a rate that exceeds the capacity of the evaporator and as a result liquid will enter the suction line., In this HVAC Training Video, I Show 4 Examples for You to Check the R-22 Refrigerant Charge Using the Subcooling Method. These 4 scenarios would be used on a..., For sale is one new slide type calculator used for calculating R 22 superheat and subcooling. This is a very useful tool that takes the guess work out of charging cooling systems. One side of this tool is a slide chart used for calculating superheat for a NON-TXV system and the other side is a slide chart used to calculate subcooling on a TXV system., The chart of military ranks is an important tool for understanding the structure of the armed forces. It provides a clear and concise overview of the various ranks and their associ..., Up to 10% lower capacity. Lubricant Recommendation: Compatible with mineral and alkylbenzene oil and if oil return becomes a concern, addition of polyolester lubricant in 5% increments could help resolve the issue. Retrofitting to: R-422B for R-22 Air Conditioning page 95. R-422B for R-22 Refrigeration page 95., Here’s a step-by-step guide on how to read a refrigerant P-H chart: 1. Understand the axes: The P-H chart typically has the pressure (P) axis on the y-axis and the enthalpy (H) axis on the x-axis. The pressure is usually measured in units like psi, kPa, or bar, while the enthalpy is measured in units like Btu/lb, kJ/kg, or kcal/kg., In this HVAC Training Video, I show you How to Read the Refrigerant P/T Chart for the Pressure-Temperature Relationship. This is used to determine the Temper..., The pressure-enthalpy chart, as shown in Fig. 2, displays all the pertinent properties for a given refrigerant (in this example R22). The bubble to the left is the portion of the diagram where the refrigerant is in the saturated condition. The blue line on the left of the bubble represents the 100% saturated liquid line,, 25 Apr 2017 ... We'll identify different superheat chart measuring systems like the R22 superheat chart ... subcooling is the correct method of ... chart. For ..., Measure compressor in temperature on the suction line near the compressor. 5. Calculate the amount of compressor superheat. Compressor superheat is all the superheat the compressor “sees.”. It is a combination of evaporator and suction line superheat. Compressor superheat is sometimes referred to as total superheat. 6., R22 superheat subcooling calculator charging chart on galleon philippinesSuperheat and subcooling charging charts Charging chart basicsCharging chart for r22 – pathway.lovelysheetworkbase.co. R410a r22 phlogR22 suction pressure temperature chart R22 chart 1R22 refrigerant subcooling superheat gauge 410a hvac., R22 chart superheat charging temperature curves line system orifice split liquid subcooling r410a cooling tables compressor metering txv device yorkR-134a / r-1234yf magnetic pressure temperature chart 8"x5.5" eur 9,96 Mua r22 superheat subcooling calculator charging chart trên amazon mỹChart r22 superheat subcooling …, from $17.89. Other New from $17.89. Select delivery location. See All Buying Options. R410a Superheat Subcooling Calculator Charging Chart Cards – January 1, 2007. by HVACcharts (Author) 4.4 211 ratings. See all formats and editions. This is a very useful tool that takes the guess work out of charging cooling systems., Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system., Use a fixed orifice charging chart like the one pictured below to obtain proper superheat. For Example, if the wet bulb temp reading is 68°F and the outdoor dry bulb temp reading is 90°F then the required superheat will be 14°F, according to the charging chart below. Superheat with a TXV. HVAC systems containing a TXV should be charged by ..., R407c is an HFC refrigerant that will replace the R22 refrigerant, as per Montreal Protocol. It is a mixture of R32 (23%), R125 (25%), and R134a (52%) that has a boiling point of -46.84°F. The same as R22, due to useful pressure-temperature properties, R407c is used in air conditioning systems, cars, and refrigeration units. Below, you will ..., HVAC App to Calculate Subcooling. Our Pressure Temperature Chart for the selected refrigerant is available for quick access; just use the button labeled (P/T). Use the refrigerant drop down for access to over 100 refrigerants. Plus and minus buttons add and subtract values in intervals of 1 to their related input fields. , May 14, 2014 · But if you take a charging chart and plug in the numbers, it comes out the same. +/- a cou [ple of degrees. example: Carrier R22 chart wet bulb 66 condenser 90 required Sh 13 @70 psi suction. 3 x 66=198 198-80= 118 118 - 90=28 28/2 =14 sh Don't know why but it works. Doug.