Limit circuit fault furnace

To read American Standard furnace codes, you need to check the color and the number of flashes of the LED display. Each color and number combination has a different meaning and indicates a different issue. Here is a summary of what each color and number means: Green flashes: Normal operation. One green flash: No call for heat.

Limit circuit fault furnace. 20317 posts · Joined 2014. #2 · Nov 10, 2016 (Edited) You have to check the resistance of the limit when the furnace stops working, then figure why it's tripping. with a limit trip, the fan will continue to run but the burners and inducer will shut off. You can't check ohms with the limit switch connected btw - it will backfeed through the board.

Blower is on after start-up (gas furnaces) / Blower calibration lockout (electric furnaces) 13: Limit circuit/switch lockout: 14: Ignition lockout: 21: Gas heating lockout (gas furnaces) / Invalid model selection (electric furnaces) ... Low-pressure switch fault (gas furnaces) / Low voltage detected (electric furnaces)

Limit switches don't usually wear out by themselves. They are a safety device that is never actually intended to be used. So it should last the life of the furnace. Even if they do get a lot of use (if an air filter gets neglected and clogged), the airflow issue can be corrected and the defective limit switch can be replaced.Mounts to furnace above combustion area. On the high limit fiber plate it should give numbers like 200L-40, meaning it trips out ("opens") at 200 (instantly shutting down the burners) and will "close" at 160. The other switch with the red pin, is another limit switch that trips out if the exhaust gas temp is too high.limit circuit fault model number is carrier I guess it is a payne furnace, the model number is pg9mab. The top part 10-07-14, (limit circuit fault),,furnace. Bryant/Carrier/Payne Fan Coil Filter KFAFK0312LRG - 19 3/4 x 21 1/ 2 x 1 - ReplacementIf your furnace is malfunctioning, the problem could very well be a faulty limit switch, but since it's a safety device, it may be operating normally, and the culprit could be something else. Testing a limit switch is a DIY task that requires only a screwdriver and a multimeter, and if the switch is faulty, it's easy to replace. Video of the Day.Status codes 4 + 2. Inducer motor fault. Proper vent sizing; restricted vent; failed inducer motor; improper motor wiring; a blockage in the tubing to the pressure switch assembly. Status codes 4 + 3. The low or medium pressure switch is open while the medium or high-pressure switch is closed.

FIX: Occurs if the unit is powered up during a call for heat or opens while the blower is on delay. CODE: 6 + 1. PROBLEM: Ignition lockout. FIX: Control will auto-reset after 3 hours. CODE: LED is off. PROBLEM: Secondary voltage fuse is open. FIX: Check whether the door switch isn’t closed or for a short circuit.For the sake of thoroughness, my explanation is long, but it should be an OK read, or maybe even interesting. I recently moved into a house which has a 3 year old KeepRite 100 KBTU/H residential furnace (N9MSB1002114A1 - 92% AFUE) that is constantly setting off the high temperature limit switch. I originally noticed this because I installed a new digital thermostat, which would lose power ...replaced all 4 limit switches replaced flame sensor Troubleshooting Tech Did verified that all the Limit switches are good. Verified heat exchanger is not cracked or damaged. checked blower capacitor, wheel and housing removed exhaust pipping and found white ashy dust blocking the sensor. He cleaned it out and put it back together.Turn off the thermostat. Before heading to reset the furnace, be sure to turn your thermostat to the "Off" position. 2. Flip the circuit breaker. Go to the circuit breaker and flip the switch that corresponds to the furnace. After flipping the switch, move it back in the previous direction after about 4 to 5 seconds.If air flow is restricted the heat is not dissipated quickly enough, and the high limit switch will kick in as the furnace overheats. Make sure the filter is clean, and the appropriate density for your furnace. If a different filter does not fix the issue, it may be caused by an under powered blower motor. -My Carrier furnace is blinking code 13: limit circuit lockout. If I unplug the furnace and plug back in with the thermostat set in the off position, I get a continuous red light, which the code reads Control has 24VAC Power. When I turn on heat, the heat blowers run, and then the fan comes on. When this happens the Code switches to 33.LIMIT CIRCUIT FAULT – Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset.Atwood furnace ignition lockout fault happens due to 3 possible reasons. Let's learn the reasons in detail to solve the problem efficiently. 1. Faulty Flame Sensor. When you face a furnace lockout, check the condition of the flame sensor. This is the first thing you will need to do without fail. The faulty flame sensor is one of the common ...

Ducane furnace model no. MPGA075B3B led fault code flashes 4 times high limit circuit open how can i fix it, change it, - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.Gas and Oil Home Heating Furnaces - Nordyne G6RA 80+ Furnace - red light flashes once, no heat, blower continuous - No heat today - red light w/ 1 flash (= Limit Circuit Open or External Load on W ). Thermo fan is on Auto , Temp is off , but blower still runs. I cut power at panel for 1 minute, turned breaker back on,Just purchased house a few weeks ago. Furnace was working initially, but now it's not. Blows cold air and has a red light that flashes 9 times. Researched and found that 9 Flashes is either "Check Ignition" or "Check Ignitor Circuit and Line "N" to 24VAC "Common" voltage (≤ 2 volts) [possible grounding problem]".carrier furnace weather maker 8000 - the blower works then sounds like electrical connection buzzing for about 3 to 4 minutes (estimant) and the furnace does not fire and then stops. a red/orange ligh …33 LIMIT CIRCUIT FAULT - Indicates the limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open or the furnace is operating in high-heat only mode due to 2 successive low heat limit trips. Blower will run for 4 minutes or until open switch remakes whichever is longer. Page 33: Cleaning And/Or Replacing Air Filter 6.Find the most common problems that can cause a Arcoaire Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Track Order ... Lid & Cover Parts Arcoaire Capacitor Parts Arcoaire Circuit Board & Timer Parts Arcoaire Compressor & Sealed System Parts Arcoaire Door Parts Arcoaire Drip ...

Happi delta 10 disposable charging instructions.

Plus I can repair anything myself as well and have all the tools, so no need for a tech and the cost of one. Here are my specs: Infinity Carrier. Furnace: 58MVC080-F-10114. software version: CEDR131312-13. SYSTXCCITC01-B. software version: 131626-03.60. Lennox PureAir model: PCO14-23. Thanks in advance!Step 2: Locate the Heating Duct. To locate the limit switch, you must first locate the heating ducts on your furnace. The ducts are typically located in the home's basement or utility closet. The panel holding the limit switch is located underneath the duct.Solution: If the draft blower starts - you hear it hum - but the furnace doesn't ignite, the problem could be caused by a blockage in the vent. This is not super-common, but something to consider if other solutions don't work. 6. The High Limit Switch is Open.Reason 7: High Limit Switch & Roll-Out Switch. A blinking red light may also indicate issues with the high limit switch or roll-out switch. The high-limit switch monitors the temperature of the heat exchanger, while roll-out switches monitor for heat in areas where it should not be present. Solution: Inspect and clean or replace the switches as ...4 posts · Joined 2012. #1 · Nov 23, 2012. My American Standard Freedom 90 Furnace only ignites about 50% of the time. It appears that the ignitor turns off a split second before the gas valve is opened. I replaced the ignitor hoping that a new one would get hotter and stay hotter for a split second longer, but it still only works about 50% of ...The electrical system that powers your furnace has likely shorted. Reset the circuit breaker that's associated with your furnace. Igniter: ... Twinning fault. 22: Main limit open. 26: Line and neutral reversed. 33: MRLC (manual reset limit control) (aka roll-out) open. 55:

When a heat call ends, my furnace control board (Emerson 50M56-495) is supposed to keep the inducer fan on for a little bit (maybe 10 seconds) and keep the circulator fan on for another minute or so (it can be set to 60, 100, 140, or 180 seconds via dip switches) to dissipate the heat. That is not happening currently. When a heat call ends ...LED Indicator Meaning; Green LED4 On: Furnace operating in low heat. Red LED1 On: Furnace in emergency heat mode. Red LED2 Flashing: Reversed line voltage polarity.A solid red light on the furnace circuit control board means it has power and is waiting on call for heat. ... Stored status codes are erased when power(115VAC or 24VAC) to control is interrupted or 48 hours after each fault is cleared: 12: BLOWER ON AFTER POWER UP (115VAC or 24 VAC) - Blower runs for 90 seconds,if unit is powered up during a ...The Bryant Legacy Plus 90 is a single-stage gas rated furnace with an AFUE rating of 95.5%. The Plus 90 utilizes Bryant's Fan On Plus technology to improve air circulation and fan monitoring. The furnace is made with a low-noise combustion system for silent operation and a high-efficiency air filter cabinet to enhance air quality.Page 59 TROUBLESHOOTING Green Amber Symptoms Fault Description Check Cautions LED Code LED Code LED Code •Temperature rise, duct static, •Furnace does not •Four •Open limit circuit, main •Confirm electrically safe gas pressure, burner alignment, operate, four Red •None •None repeating limit, aux limit, or roll out condition before ...This is caused by a dirty filter, a dirty evaporator coil (number one reason if the evaporator is over 10 years of age), an improper rpm output or malfunctioning blower motor. The best way to go about testing the limit is to first find out what the limit cut off temperature is. On the limit it will have something like 140-20 or 160-20.Just purchased house a few weeks ago. Furnace was working initially, but now it's not. Blows cold air and has a red light that flashes 9 times. Researched and found that 9 Flashes is either "Check Ignition" or "Check Ignitor Circuit and Line "N" to 24VAC "Common" voltage (≤ 2 volts) [possible grounding problem]".There may be more than one disconnect switch, including accessory heater(s). Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program. For verification of certification for individual products, go to www.ahridirectory.org . 441 03 1402 00. Nov. 2012. I have a 2019 92% 80K BTU Heil gas furnace that started giving me a Code 4 'Limit Circuit Fault' for the past couple of weeks. The furnace will run for about 5 minutes, cycle itself off, and then turn back on until it reaches the set temperature. I called a service tech last week who thinks it could be undersized venting. Meaning: Indicates a limit circuit fault, such as a flame rollout or an open limit, which are serious safety concerns. Action: Check for a loose blower wheel, blocked vent, correct vent sizing, dirty filter, or a defective blower motor. Ensure that all connections and switches are functioning properly.

A carrier furnace code 13 indicates that the limit switch is open. If the limit switch opens 5 times for at least 3 minutes each time during 1 thermostat cycle this will trigger the status code 13. This status code is associated with overheating within the furnace causing the limit switch to open. With that said, there are a few things that can ...

Received 2 Upvotes on 2 Posts. Welcome to the forums!! An open limit switch is indicative of an over temperature condition and is usually caused by a dirty/clogged air filter, a blocked/restricted vent pipe, an obstructed return air duct, or a dirty/clogged a/c evaporator coil (if equipped). The most common cause is an air filter that has not ...Carrier Fault Code 179 - Outdoor Unit Communication. First things first, make sure that you have power to the outdoor unit. If this part of the system is not receiving any power, then it will not register. Also, do check the outdoor circuit board - there shouldn't be any blown fuses or tripped breakers.CODE: Status codes 3 + 5. PROBLEM: Gas valve fault. FIX: RED, YELLOW, or ORANGE wire at the gas valve. CODE: Status codes 4 + 1. PROBLEM: Blower motor fault. FIX: Blower failed to reach 250 RPM, or the blower failed to communicate within the prescribed time limits. CODE: Status codes 4 + 2.EL296UHV Series furnace pdf manual download. Also for: El296uhvx series, El296uh045xv36b, El296uh070xv36b, El296uh090xv36c, El296uh090xv48c, El296uh090xv60c, El296uh110xv48c, El296uh110xv60c, El296uh135xv60d. ... Will clear after fault recovered. If un- able to operate 2nd stage, replace control. ... and opens the circuit to the furnace control ...* Update: I replaced the filter and that fixed the problem. Hope this helps and saves you some money.Here is short video showing how to read the blinking e...Maytag gas furnace - the burner kicks in and runs for 30 secs, burner shuts off, flashes code 1--limit circuit open or external load on "W". Then blower wil kick in for short time and then kick off. T …Atwood furnace fault codes: Atwood is a famous company that manufactures these furnaces. ... this indicates a hard lockout and a failure with the internal circuit board. A flashing light with a single flash repeated after a 3 second pause - this indicates a problem with the airflow or the limit switch, and it can be reset after the fault is ...

La pulga mas grande de dallas tx.

Yaya panton age.

Try these 6 steps for troubleshooting a gas valve: 1. Gas Valve Wires. Cracked or frayed wires could indicate that you need to replace your furnace due to its age or that something has scorched the wire. If the wire looks disabled in any way, replace it and continue your diagnosis.Limit circuit fault on a Bryant gas furnace. Related Topics HVAC Skilled trades Careers comments sorted by Best Top New Controversial Q&A Add a Comment raulg45bdn • Additional comment actions. Take a temperature reading in the supply plenum, if its above 130F possibly the unit is going off on limit and is working properly. ...Gas and Oil Home Heating Furnaces - Limit circuit fault but house keeps warm - I read all of the messages I could find on the forum about this problem before posting. Please see below where I post my analysis and what I have tried so far. Please let me know if you have any ideas. Thank you in advance for your input. ISwitch furnace coleman limit replacement parts evcon rollout s1 luxaire direct york amazon available36t01b3 furnace limit switch l155-30f – tzsupplies.com Lockout furnace inspectapedia boiler blower honeywellMy furnace is giving me an fault condition of limit circuit open or. Furnace rollout limit switch l180f onetrip parts® direct ...[4] LIMIT CIRCUIT FAULT - Indicates the limit or a flame rollout switch is open or the furnace is operating in high-heat only mode due to 2 successive low-heat limit trips. Blower will run for 4 min. or until open switch remakes whichever is longer. If open longer than 3 min., code changes to lockout #7.The problem might be a defective pressure switch, blower motor, or capacitor. Code 3-3. Limit switch or flame roll-out switch is open. Clean the filter (or replace it with a new one) and make sure that the vents are not obstructed. In some cases, the blower wheel might be loose or you may have a defective blower.Here are some common methods used to reset Bryant furnace codes:Using the SW-1 Button:a. Locate the control board on your Bryant furnace.b. Identify the SW-1 button, usually found on the control board.c. Press and release the SW-1 button.d. Wait for a few seconds to allow the reset process to complete.e.17 Dec 2019 ... Multimeter Training - Multimeter Safety | TPC Training · Furnace Overheating - 10 Reasons Why · What is the Difference Between a Short Circuit and&nbs... ….

Meaning: Indicates a limit circuit fault, such as a flame rollout or an open limit, which are serious safety concerns. Action: Check for a loose blower wheel, blocked vent, correct vent sizing, dirty filter, or a defective blower motor. Ensure that all connections and switches are functioning properly.This video provides step-by-step instructions for replacing the limit switch on Payne furnaces. The most common reason for replacing the limit switch is the ...Just purchased house a few weeks ago. Furnace was working initially, but now it's not. Blows cold air and has a red light that flashes 9 times. Researched and found that 9 Flashes is either "Check Ignition" or "Check Ignitor Circuit and Line "N" to 24VAC "Common" voltage (≤ 2 volts) [possible grounding problem]".See full list on hvac-boss.com 58MVC060-F-10114 Parts & Furnace Model Repair Help. Find the right Carrier Furnace Model 58MVC060-F-10114 replacement parts for your repair. Filter results by part category, part title and lawn mower symptoms. You can also view 58MVC060-F-10114 parts diagrams and manuals, watch related videos or review common problems that may help answer your questions to get started on fixing your Furnace model.I have a limit circuit fault code 33 - Answered by a verified HVAC Technician. ... my programmable carrier thermostat screen goes blank when the furnace trips off from the hi limit switch. the light comes on when i reset the limit switch .The code is 33 all the time when it happens, ...replaced all 4 limit switches replaced flame sensor Troubleshooting Tech Did verified that all the Limit switches are good. Verified heat exchanger is not cracked or damaged. checked blower capacitor, wheel and housing removed exhaust pipping and found white ashy dust blocking the sensor. He cleaned it out and put it back together.Raypak high limit 1 fault and 2 fault indicates that the High limit has exceeded the 135F temperature. The HL switches will open due to the raising temperature inside the inlet/outlet header up to 135 - 140 F. ... The heat exchanger is one type of metal alloy tube of the heater which transfers heat energy from a hot water circuit to the cooler ... Limit circuit fault furnace, There’s a limited circuit lockout with your furnace. The lockout happens when the limit/flame rollout stays open for more than 3 minutes. It will take three hours for the control to auto-reset. CODE 8 flashes. Code 8 flashes inform that the gas heating is in a lockout. The auto-reset of the control won’t take place. , The furnace will start up in either intermediate-, or maximum-heat. The furnace will transition and operate at minimum-heat or the calculated modulating rate after starting and operating for 45 seconds at intermediate-heat. The furnace control CPU defaults to minimum-heat on the first thermostat cycle and calculates the modulating rate, In the spring, my Carrier Infinity (model 58MVC100-F-10120) stopped working and was blinking code 33, limit circuit fault, due to the flame rollout switch tripping. We had an HVAC tech look at it, and diagnosed a cracked heat exchanger. The weather was getting warmer and finances were tight, so we put off having it repaired, and the tech closed ..., Code 33 on Carrier and Bryant furnaces is caused by a lack of airflow. If the issue is not resolved in time, it may develop to code 13, caused by safety lockout. Code 33 is a Limit Circuit Fault code. This means that the flame rollout switch is open. If the high limit or flame rollout switch is open, you will experience error code 13., [4] LIMIT CIRCUIT FAULT - Indicates the limit or a flame rollout switch is open or the furnace is operating in high-heat only mode due to 2 successive low-heat limit trips. Blower will run for 4 min. or until open switch remakes whichever is longer. If open longer than 3 min., code changes to lockout #7., But if i turn the power off then on, at first its just the blower, then the gas sound then the flames are on for maybe 5 minutes when it kicks off the light starts blinking and it says "limit circuit lockout- lockout occurs if the limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open longer than 3 minutes., Feb 14, 2018 · Learn how to troubleshoot an open limit fault on a furnace. These tips are for licensed HVAC technicians only. For more tips visit edgetekhvac.com , 33. LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires manual reset., Carrier model 58sta070-12...flashing code 33,(limit circuit fault),,,,furnace ignites,blower barely turns for - Answered by a verified Home Improvement Expert. We use cookies to give you the best possible experience on our website., I have a 2019 92% 80K BTU Heil gas furnace that started giving me a Code 4 'Limit Circuit Fault' for the past couple of weeks. The furnace will run for about 5 minutes, cycle itself off, and then turn back on until it reaches the set temperature. I called a service tech last week who thinks it could be undersized venting., My bryant gas heater is displaying a code 13 limit switch lockout and after 3 hours and the manual reset has been activated it comes on and works till the thermostat reads about 60-61 degrees and then shuts off. I've replaced the air filter and used some sandpaper to clean off the sensor rod that sits on the left side of the burner., This video provides step-by-step instructions for replacing the limit switch on Payne furnaces. The most common reason for replacing the limit switch is the ..., CODE: 7 RED FLASHES RESULT: This fault code indicates that the flame could not be established. This no-light condition occurred 3 times (2 retries) during the call for heat before locking out. FIX: Low gas pressure, faulty gas valve, dirty or faulty flame sensor, faulty hot surface ignitor or burner problem may cause this. The furnace will lock out for one hour and then restart., Whenever you get a limit circuit lockout, you must ask why it's happening. The manufacturer's literature should explain the fault code and may even list possible causes, but it's up to the tech to identify the source of the problem. If you have a high-limit fault, verify that the switch is actually open with your meter., Your Furnace needs the right kind of ignitor to work. Even if it worked, if it was the wrong ignitor, you should replace it. Bad limiter switch. If it's faulty the switch shuts off your Furnace if the temperature gets too hot. Overpowered. If the breaker box blows when the Furnace comes on, your ignitor can't handle a power surge., Check the circuit breaker or fuse box to ensure the furnace is getting power and hasn't tripped a circuit breaker. Check the pilot light if you are using an older furnace. ... which in turn can cause the heat exchanger to overheat, tripping the high limit switch and shutting down the furnace. Check to ensure room air vents are open and ..., Furnace turns on and will ignite then the gas immediately shuts off and the blower remains on. Error code is 33 then changes to 13., Code 1-3: Indicates that a limit flame switch problem that normally auto-resets after 3 hours. Code 1-4: Represents an ignition problem. However, the furnace will auto-reset after some hours. Code 2-1: This is a sign of gas heating lockout. You need to check if the gas valve wiring is correct., Furnace shut off with "Limit Switch Lockout" (code 13). Works for 24 hours after a reset, power cycle. ... and then furnace does function throughout the day. If I just power cycle (and don't press the reset switch) I get a limit circuit fault, code 33. ... had that happen on a 12-year-old Carrier that was throwing limit faults., Flash Code on Outdoor Board: 3 for 38TDB, YDB 598B, 698B models and 53 for 24ANA, 25HNA 187A, 180A, 286A, 288A. Fault description: Outside Temp Sensor issue. Potential cause and action: Ohm out sensor and check wiring. May also indicate lost communication with the outdoor unit. Flash Code on Outdoor Board: 4 for 38TDB, YDB 598B, 698B models and ..., 33 LIMIT CIRCUIT FAULT - Indicates the limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open or the furnace is operating in high-heat only mode due to 2 successive low heat limit trips. Blower will run for 4 minutes or until open switch remakes whichever is longer. Page 33: Cleaning And/Or Replacing Air Filter 6., Find the most common problems that can cause a Arcoaire Furnace not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Track Order ... Lid & Cover Parts Arcoaire Capacitor Parts Arcoaire Circuit Board & Timer Parts Arcoaire Compressor & Sealed System Parts Arcoaire Door Parts Arcoaire Drip ..., Shut off power to the furnace and remove the access panel. Locate the high limit switch. It is usually found screwed into the plenum somewhere above the burners. Remove the high limit switch from the plenum by unscrewing it and taking out the wire connectors. Note: Do not touch the sensor., Limit circuit fault: either a limit or flame rollout is open: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower: Five LED flashes: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized: Check for a leaky gas valve or a gas valve that is stuck open ..., Test – Check for proper airflow and use a multimeter or observe the flame sensor light. Reset – Gently press each arm of the limit switch till you hear a click. Turn On Power – T urn back on the power and let the furnace go to auto mode. Refer to the user manual if you’re stuck., A clogged air filter can cause other problems, such as poor airflow and decreased efficiency. Other causes of Carrier furnace fault code 13 limit lockout can include: a faulty thermostat, a faulty blower motor, a faulty igniter, a faulty flame sensor, or a faulty control board. How to Troubleshoot Carrier Furnace Fault Code 13 Limit Lockout, 28 Oct 2012 ... A guide to determining if the limit has failed and if so why. This video is part of the heating and cooling series of training videos made ..., I have a Nordyne G6RA mid efficiency furnace that was installed about 6 years ago. The problem is that the furnace continuelly kicks out on supplu air hi limit after about 5 min. The furnace then will … read more, Mounts to furnace above combustion area. On the high limit fiber plate it should give numbers like 200L-40, meaning it trips out ("opens") at 200 (instantly shutting down the burners) and will "close" at 160. The other switch with the red pin, is another limit switch that trips out if the exhaust gas temp is too high., The furnace will start up in either intermediate-, or maximum-heat. The furnace will transition and operate at minimum-heat or the calculated modulating rate after starting and operating for 45 seconds at intermediate-heat. The furnace control CPU defaults to minimum-heat on the first thermostat cycle and calculates the modulating rate, Limit circuit fault: either a limit or flame rollout is open: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower: Five LED flashes: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized: Check for a leaky gas valve or a gas valve that is stuck open ..., Generally, a furnace doesn't respond to the thermostat due to a clogged air filter, the wrong installment for the thermostat, loose and damaged wiring, a defective circuit breaker, or blown fuses. Well, to fix the issue, do the followings-1. First of all, check the circuit breaker and the surrounding wirings. 2., On the "first" call for heat, the high limit has cooled enough that the inducer comes on and the burner lights. When the high limit trips, the indoor fan and inducer continue to run until the limit cools, then lights the burner again. It continues this cycle until the thermostat is satisfied. I get 4 flashes on the board, High Limit, but the ...