If code hayward heater

LP Error is usually LOW PRESSURE - low refrigerant charge, but on a HEAT PUMP if the condenser fan isn't working, you will also enable the low pressure senso...

If code hayward heater. Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:

Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:

Diagnostic Codes and Part Numbers 19-20 1. Heater not powering up 21-26 2. Open FC1&/FC2 Fuse 27-28 3. Open FC3&/F1 Fuse 29-31 4. Open FC4 Fuse 32-33 5. "D" ode 34-35 ... Hayward Part # FDXLFSK19F30 (Qty. 10) G . The control continually compares the set temp to the actual water temp. WhenLochinvar EnergyRite 202 Gas Pool Heater, 202,000 BTU. CODE: ERN202 / ERLP202. Lochinvar EnergyRite 252 Gas Pool Heater, 250,000 BTU. CODE: ERN252 / ERLP252. Hayward H-Series H250FD pool heater has 250,000 BTUs, electronic ignition, and capabilities for natural gas or propane. Great option for mid-sized pools.Ensure the proper installation of the main circuit board within the heater. Check the short ground and high voltage issue and take steps to prevent it. 5. Circuit Board's Faulty Fuse. Another factor responsible for displaying the Hayward pool heater ce code is the faulty or blown fuse in the heater's circuit board.Test 2: Load Pressure Test. Here the aim is to check and measure if the gas supply or pressure holds up when the heater is in use. The manometer should again be attached to the INLET section of the gas valve. When conducting this test the Hayward pool heater should be turned to the on position. If your manometer reading is showing low loads ...The Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Hayward H200FDN pool heater stopped working during the couple of days of heavy rain late last week. There is power to it, can hear a buzzing inside. Changed the low voltage fuse, fan came on briefly.Hayward H200FDN pool heater stopped working during the couple of days of heavy rain late last week. There is power to it, can hear a buzzing inside. Changed the low voltage fuse, fan came on briefly.View and Download Hayward H150FD owner's manual online. POOL AND SPA/HOT TUB HEATERS. H150FD swimming pool heater pdf manual download. Also for: H350fd, H400fd ...

H Series MV and ED2 Manual. 1302704001 Rev E mmyy. Title. H Series MV and ED2 Manual. Author. Hayward Pool Products. Created Date. 8/6/2008 8:30:42 PM.Hayward Heat Pump Lock Out FeaturePlaster. Chlorine. Salt Water Generator. SWG Type. Pentair Intellichlor IC-60. Aug 27, 2021. #2. Welcome to TFP. b0 code simple means the heater is being controlled by the remote 2 wire connection to your Prologic and will not respond to the keypad controls.May 26, 2022 · The control board oversees the operation of your heater, including monitoring temperature and safety features. In short, the Hayward Heater bD Code means there is a problem with the control board located on the right side of the heater. This can be caused by an open FC4 Fuse, faulty wiring, or a secondary high voltage fault. Dealing with the Hayward Heater HS IO code can be challenging, but with the right knowledge, preventive measures, and a willingness to explore advanced options, you can maintain a reliable and safe heating system for your pool or spa. Remember that safety should always be a top priority when working with gas appliances, and don't hesitate to ...

View and Download Hayward H150 installation, operation and service manual online. H150 swimming pool heater pdf manual download. Also for: H250, H200, H300, H350, H400, H210.View online or download Hayward H250FDN Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H250FDN; Hayward H250FDN Manuals. Manuals and User Guides for Hayward H250FDN. We have 6 Hayward H250FDN manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. …Make sure that the heater is in POOL or SPA mode. Press the MODE button on the user panel keypads to set the heater on STANDBY mode. On STANDBY mode, the heater will not heat the water. Press and hold the MODE and DOWN buttons for at least three seconds. The panel should display BO, which means bypass operation.When it comes to hayward heaters, there are some common bd codes that you might encounter. Bd1 indicates ignition failure, which can often be resolved by cleaning the ignition assembly. Bd2 suggests water temperature sensor failure, which can occur due to a faulty sensor or connection issue. If you see bd3, it indicates high limit switch open ...

4520 sunset boulevard.

According to Hayward, and every one of those heaters I've worked on, a 3-second or less signal (voltage) at the main valve indicates that the boards need to be replaced. Reply. ... After the third attempt, I get the "IF" code. On a side, when the heater was functioning, I always would smell gas when it ignited. Now when I attempt to ignite it ...Pool and Spa Expert: ScottyT1119. If the wire and connection for the temperature sensor isn't messed up or faulty, then your control board is the culprit since you have replaced the sensor already. You may be able to take a multi meter and chheck there is any power going to the sensor from the control board.Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:Step 1. Turn off the power supply to the pool heater. Step 2. Wait for at least five minutes to allow the heater to cool down. Step 3. Turn the power back on and press the reset button. This button is typically located near the heater's control panel or on the heater's interior.Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support.These Hayward pool heater troubleshooting codes and explanations will help you fix the problem. Skip to content ☏ Click to call: 407-786-0000. Services Menu Toggle. Pool Heat Pump Repair Menu Toggle. Schedule …

The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors. The energy efficiency of the Universal H-Series gas heater ...View online or download Hayward H200FDN Troubleshooting Manual. ... Brands; Hayward Manuals; Heater; H200FDN; Hayward H200FDN Manuals. Manuals and User Guides for Hayward H200FDN. We have 2 Hayward H200FDN manuals available for free PDF download ... Diagnostic Codes and Part Numbers. 19. Troubleshooting Guide. 20. …We have 1 Hayward H200FDP manual available for free PDF download: Troubleshooting Manual Hayward H200FDP Troubleshooting Manual (65 pages) universal h series heatersJun 23, 2021 ... My pool heater would not fire and was showing the LO (low flow) code. This shows where the adjustment knob is on the pressure switch and ...You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the "bO" message should appear ...Pool Heater Service Call - Hayward Heat Pro Heat Pump with LP Error on display. LP is Low Pressure. We found a leak on the filter dryer, discussed with home...Pentair Heaters - 40-120 GPM. Hayward -40-70 GPM. Check your pool filters to ensure proper flow. ... Find the light that is illuminated to see what code your heater is presenting. To gain access to these additional codes you will need to remove two of the heater side panels. Make sure to disconnect the power to the heater by shutting off the ... Universal H-Series Natural Gas 400,000 BTU Low NOx. Hayward. SKU: H400FDN. The Universal H-Series is an energy efficient, high performance, installation adaptable commitment to the pool service professional. Add to Compare. Add to Export. What to do if the pilot light for your pool heater is not turning on or if the pilot light is not lasting very long or pilot outage. We'll go over on how to ...Diagnostic Codes For Hayward Heat PumpTurn the thermostat all the way up on the heat pump. These units are not compatible with 3 wire remotes. For 2 wire air switch installations remove the jumper between terminals 1 & 2 and replace it with the 2 wires from your switch. Set the thermostat on the heat pump to the desired temp. Wiring Diagram HPABG / HP380.

Use the “Mode” key to change your heater’s settings. Select the “Standby” Option and put the heater on it. Press the remote’s “Down” key and hold it and then press the Mode key and hold it simultaneously. For 3 seconds, hold down both the “Down” and “Mode” keys as long as the “bo” code doesn’t remove from your ...

What to do if the pilot light for your pool heater is not turning on or if the pilot light is not lasting very long or pilot outage. We'll go over on how to ...The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors.Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools.Hayward H250 Quick Manual (4 pages) Universal H-Series POOL AND SPA HEATERS. Brand: Hayward | Category: Swimming Pool Heater | Size: 0.8 MB. Hayward H250 Pdf User Manuals. View online or download Hayward H250 Installation, Operation & Service Procedures, Installation, Operation And Service Manual, Quick Manual.The Hayward HeatPro Heat Pump is listed by ETL as complying with the latest edition of the "UL Standard for Safety for Heating and Cooling Equipment", UL1995 and CSA C22.2 No. 236. All Hayward HeatPro Heat Pumps must be installed in accordance with all applicable National and Local codes. In the absenceFixing a Hayward Heater LO Code: Step-by-Step… Solve Hayward Pool Heater BO Code: Easy… Sta-Rite Pool Heater Troubleshooting: Quick Fixes… Pentair MasterTemp 400: Fix a Flashing Heating Light… Pentair MasterTemp 400: Fixing Ignition Lockout Issues; Decode Richmond Water Heater Blinking Light Codes:…Below is a list of all Diagnostic Codes for the UHS Heater. Troubleshooting Steps for each Code are covered on the following pages. IF. IO. LO. PF. HE. HF. HS. SB. SF. Diagnostic Code . AC. AO. BD. CE. EE. ... Hayward In Ground Pool/Spa Gas Heaters. Operations Manual ; York D3CG090. Installation manual ; Unitary products group DJ 036 ...Jan 19, 2010 · On 1/27/2010 at 7:57 AM, txpoolguy said: CE code indicates "Communication Error". Problem is communication between integrated control board and display board. Display board (DB) is the one mounted on the backside of the keypad. Integrated control board (ICB) is the one back in the heater behind the display board.

Ceres bakery inc kalispell mt.

Fema camp locations in the united states.

Enter a postal code to find the nearest Hayward authorized pool professional. ... Heaters (not including Heat Pumps) Heat Pumps. Lighting. Pumps. Variable Speed Pumps ... Aug 28, 2021 ... Has your heater ever displayed an E01 or E02? figure out why and how to fix it here! We hope this video helped. To schedule a service, ...The Hayward Heater AO Code occurs when the blower vacuum switch does not close after the blower starts, when the blower switch opens unexpectedly during the operation, or when the blower prover switch opens during the post-purge cycle (when the heater is not firing). A: (From Tim David, Owner of Airlucent) Of course, I’d be happy to …Jan 19, 2010 · On 1/27/2010 at 7:57 AM, txpoolguy said: CE code indicates "Communication Error". Problem is communication between integrated control board and display board. Display board (DB) is the one mounted on the backside of the keypad. Integrated control board (ICB) is the one back in the heater behind the display board. IF heater is installed in an outdoor environment, go to step 11I. 49 Applies To ; Hayward H400FDN | Universal H Series Troubleshooting Guide - Page 50 Service LED ON: "LO" Code (cont.) Note: Please ensure that the vent size is sufficient for the heater model installed.View online or download Hayward H200FDN Troubleshooting Manual. ... Brands; Hayward Manuals; Heater; H200FDN; Hayward H200FDN Manuals. Manuals and User Guides for Hayward H200FDN. We have 2 Hayward H200FDN manuals available for free PDF download ... Diagnostic Codes and Part Numbers. 19. Troubleshooting Guide. 20. …Preventing Future LO Codes. To avoid encountering the Hayward Heater LO Code in the future, consider implementing these preventive measures: Regular Maintenance: Stay on top of regular maintenance tasks, such as cleaning or replacing your pool filter and inspecting your plumbing system for blockages.Universal HC Series - Dual Fuel 400k BTU. Hayward. SKU: HDF400. The industry's smallest footprint heater allows replacement of almost any heater in an existing pad with the efficient reliability of the new Universal HC Series dual-fuel technology heater from Hayward®. Add to Compare. Add to Export. Overview.The heater attempts to light the burner three times before displaying the IF code and shutting down. The code protects the heater from damage caused by a gas buildup or other ignition-related problems. Common Causes of the Hayward Heater IF Code. There are several reasons your Hayward heater may be displaying the IF code.View and Download Hayward H250IDL2 installation, operation & service instructions online. Pool and Spa/Hot Tub Heaters. H250IDL2 swimming pool heater pdf manual download. Also for: H350idl2, H400idl2.Hi, I am getting an AO error on a friends Hayward Gas heater. The heater blower vacuum switch (rss-495-061) seems to work when I suck very lightly on it...was getting CE code, aka Communication Error. Replaced main board, display board, and display panel. ….

May 6, 2023 · Pool and Spa Expert: ScottyT1119. If the wire and connection for the temperature sensor isn't messed up or faulty, then your control board is the culprit since you have replaced the sensor already. You may be able to take a multi meter and chheck there is any power going to the sensor from the control board. Lochinvar EnergyRite 202 Gas Pool Heater, 202,000 BTU. CODE: ERN202 / ERLP202. Lochinvar EnergyRite 252 Gas Pool Heater, 250,000 BTU. CODE: ERN252 / ERLP252. Hayward H-Series H250FD pool heater has 250,000 BTUs, electronic ignition, and capabilities for natural gas or propane. Great option for mid-sized pools.Learn the basics of tankless water heater installation and replacement, including the cost, materials and tools needed to get the job done. By clicking "TRY IT", I agree to receive...cOP code. Replacement part HPX11024169 coil defrost sensor on heayward HP21104T.By carefully following these steps and additional advice, you should be able to effectively diagnose and resolve the AO code issue on your Hayward heater. Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page . Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. Start heater again. Does low side pressure drop below 30 psi for R-22 unit or 80 psi on a R-410A unit? Figure C. Replace LP switch. See Note 2 below NO Abandon existing switch on Hayward R-22 units. Replacement switch is a screw on switch. Use a swivel tee on the low side access port. On Summit and R-410A (4T) Hayward units the existing switch ... Diagnostic Codes Please contact a local authorized service center for service. go to: www.hayward.com and click on the “Dealer Locator”Hayward pool heaters display an “if” code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue promptly to avoid further damage to the heater. If code hayward heater, Poolservice123 : Pool Heat Pump Warranty Hayward Industries warrants that the SUMMIT pool heat pump will be free of defects in workmanship and materials. The heat pump will be warranted for a period of two (2) years*. All parts and labor to correct any defect in workmanship or materials will be the responsibility of Hayward Industries. The compressor component of the SUMMIT pool heat pump has ..., The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 400,000 BTU, Propane Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & Power, Enter a postal code to find the nearest Hayward authorized pool professional. ... Heaters (not including Heat Pumps) Heat Pumps. Lighting. Pumps. Variable Speed Pumps ..., Hayward H-Series H250IDL2 - H400IDL2 Low NOx Pool Heater Parts. Starting from $15.79. Shop Now. Hayward HeatPro HP6003T, HP11003T HP21003T HP21203T HP2100TC03T Pool Heat Pump Parts. Starting from $7.99. Shop Now. Hayward HeatPro HP1100 2100 2100TCO 600 ABGDELUXE PE42B2S PE52A PE52A6TCO Part Schematic., Oct 21, 2020 ... I describe the main causes and how to resolve the AO error if you receive one on a Hayward Heater., GAS HEATERS: Universal H-series ASME Heater: 3 Years: CHLORINE GENERATOR & UVO3 SYSTEMS: Saline C ® 6.0 & 11.0 Salt Chlorine Generators: 2 Years* None: 2 Years* None: 2 Years** 2 Years* *Salt cells carry an 18 month parts warranty. * No field labor, factory repair labor only. **Salt cells carry a 1 year full warranty & a prorated warranty for ..., Hayward Insights provides expert advice, tips, ... Heater required kW : Heater required BTU/hr : Water weight kg : Water weight Lbs : Total BTU to heat water required temp : Heater Capacity selected BTU/hr (=3413xkW) ... Scan the QR code to send us a quick information request., Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000. Hours Mon-Fri: 8am - 7pm Saturday: 9am - 5pm Sunday: By Appointment, Hayward Heater LO code. Thread starter joeg679; Start date Jul 19, 2023; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair. Pumps, Filters, and Plumbing . 1; 2; Next. 1 of 2 Go to page. Go. Next Last. J. joeg679 Member. May 28, 2017 21 NJ. Jul 19, 2023; Add bookmark #1 Hello, I was getting a Lo code on my heater …, Good afternoon; how are you this afternoon? I am sorry to hear about your BD code on your Hayward Heater. I am sure this is frustrating. We will start from the beginning; some of this may be repetitive. BD Code means Bad Board or Secondary High Voltage Fault. Remove FC4 fuse and measure continuity. Let me know if that fuse is the one you ..., I turned on my Hayward pool heater and it showed a CE code. The service light is on. I am able to press mode button and switch between standby, spa and pool. The heater goes on but cannot work temp. B … read more, Hayward heater shows code if. Contractor's Assistant: I'll do all I can to help. Tell me a bit more about what's going on so we can help you best. The gas was turned off for unrelated repair and the heater turned on when the gas supply resumed. The pilot must now be lighted. I do not see a regulator that looks like those shown in the manual., View and Download Hayward H150FDN troubleshooting manual online. universal h series heaters. H150FDN heater pdf manual download. Also for: H150fdp, H150fdpasme ..., Hayward H200FDN pool heater stopped working during the couple of days of heavy rain late last week. There is power to it, can hear a buzzing inside. Changed the low voltage fuse, fan came on briefly., I turned on my Hayward pool heater and it showed a CE code. The service light is on. I am able to press mode button and switch between standby, spa and pool. The heater goes on but cannot work temp. B … read more, Pool heaters work very straightforwardly: they generate heat to raise the water temperature. As long as they have a reliable water supply, the heater will not overheat. That’s why your unit will display the LO code when there’s something wrong with the water supply. The LO code signifies that there’s a low water pressure condition. […], Double Feature - Hungry? Hayward pool heater with ignition failure along with multiple issues. 9 years old. Time for a replacement. Cost effective solution i..., Summary of Contents for Hayward H300FD. Page 1 POOL AND SPA/HOT TUB HEATERS H150FD, H200FD, H250FD, H300FD, H350FD, H400FD & H500FD MODELS OWNER'S MANUAL FOR YOUR SAFETY WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, PRINTED 10/24/2011 AT 1:13 PM injury, or death., Diagnostic Codes Please contact a local authorized service center for service. go to: www.hayward.com and click on the “Dealer Locator”, The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 400,000 BTU, Natural Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & Power, Sep 24, 2019 · Problem Possible Cause Possible Solution; Heater cycles on & off: 1. Filter or pump baskets are dirty. 2. External bypass is out of adjustment. 3. Internal bypass is broken or stuck. , Hayward Pool Products 620 Division Street, Elizabeth NJ 07207 Phone (908)-355-7995 www.hayward.com ... heater, a valve actuator, pool and yard lighting, and more. The VS Omni offers the next generation of ... local codes require). The Hub is designed to mount vertically with the knockouts facing, HeatPro Heat Pump 140k BTU. Hayward. SKU: HP21404TC. High performance, energy-efficient HeatPro heat pumps quietly and economically maintain the ideal water temperature at all times. Add to Compare. Add to Export. Overview. Specifications., Hi everyone, I am hoping you can help me out! I have a Hayward H400 IDPL2 heater - when we opened this year I got an IF code so I cleaned out the nozzles …, Hayward 250 pool heater throwing AO code. Replaced control board, blower motor, pressure switch, igniter. Still not turning on. ..., Fixing a Hayward Heater LO Code: Step-by-Step… Solve Hayward Pool Heater BO Code: Easy… Sta-Rite Pool Heater Troubleshooting: Quick Fixes… Pentair MasterTemp 400: Fix a Flashing Heating Light… Pentair MasterTemp 400: Fixing Ignition Lockout Issues; Decode Richmond Water Heater Blinking Light Codes:…, Start heater again. Does low side pressure drop below 30 psi for R-22 unit or 80 psi on a R-410A unit? Figure C. Replace LP switch. See Note 2 below NO Abandon existing switch on Hayward R-22 units. Replacement switch is a screw on switch. Use a swivel tee on the low side access port. On Summit and R-410A (4T) Hayward units the existing switch ... , Set both the pool and spa desired temperature on the heat pump before turning on the remote. Once the remote is calling for pool or spa you will not be able to change the function on the heat pump without turning the remote off. Use Terminals 1 and 2 for 2 wire remote connection. Use Terminals 3,4,& 5., The electric heaters fit into compact spaces — even under spa skirts or steps. Like all Hayward heaters, they are easy to install and service. • 304 stainless steel tank, • 304 stainless steel threaded head, safety sensor electric heating element, • Service-ease design gives simple access to internal controls, • Heater on indicator light,, The tech did the install and ran the heater only for a few minutes to check for ignition and stuff. He had done some other plumbing work so he didn't want to run in too long, or the pool pump either, so that the PVC glue really had some time to cure. The heater is a 400,000 BTU Hayward Universal HC Series Model HDF400 Pool Heater., PREMIUM PERFORMANCE: The Hayward Universal H-Series 250,000 BTU Natural Gas Heater delivers fast premium heating performance for years of reliable, long-lasting comfort. CORROSION PROTECTION: The Universal H-Series boasts exceptional protection against corrosion and premature failure caused by unbalanced water chemistry., The Universal H-Series 400,000 BTU Natural Gas Pool & Spa Heater from Hayward provides reliable, long-lasting comfort for pools and spas with a surface area up to 1,200 ft. Built with a durable cupro nickel heat exchanger, it offers exceptional protection against corrosion and premature failure caused by unbalanced water chemistry, ensuring you ..., Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Phase Heaters: 1.0000: Pool Type: In Ground: Product Dimensions: 24 " x 25 " x 29.5 "Product Height: 24 in: Product Length: 29.5 in: Product Weight: 165 lb: Product Width: